Specifications

Table Of Contents
T-Max® Manager/Pro and T-Max® 3A User’s Guide Page 23
6.3.10 Auto Address the T-Max® System
Auto Address will allow you to reset the addresses on the timers in the room. This is typically
done on initial installation, when adding tanning beds or when you want to change the room
numbers in your salon.
Note: Make sure no one is tanning before selecting this option.
1) Click Manager Utilities then Auto Address the T-Max® System with your left mouse
button. A window will appear with the following message: Proceed with Auto Address of
Entire System? (Make sure there are no active sessions).
2) Click OK with your left mouse button of you want to proceed. Click Cancel of you do not
want to auto address the salon.
Once you click OK, the Manager Access screen will disappear and the ADNET 2000™
screen will appear. Each timer in the salon will show a 99 and be sounding an alarm. The
T-Max® Manager/Pro VFD display will show Auto Addressing Bed 00. Go to each timer
in order that you want the salon to be and press the Start/Stop buttons along the way. Each
timer will go to a 0. Make sure you press the Start/Stop buttons in order that you want the
salon addressed. Go to room 1 first, then room 2, room 3 etc. The T-Max® Mgr/Pro VFD
display will show Auto Addressing Bed XXX. XXX will be one number higher then the
number of beds addressed. Press the Enter button on the T-Max® Manager/Pro keypad.
3) On your computer, press the Start button with your left mouse button. The Manager Access
screen will reappear with the new configuration being displayed. The T-Max® Mgr/Pro can
be controlled via a computer using many third party software packages or ADNET.EXE
provided with the T-Max® Mgr/Pro.
6.4 ADNET.EXE
This is a DOS program can be used to control your salon in the event that your PCs hard disk
drive fails. To use ADNET.EXE:
Place the diskette in drive A and type the following: A: <Press the Enter key>. The
prompt will read as follows: A:\>_
Type the following: CD ADNET <press the Enter key>. The prompt will read as follows:
A:\ADNET>_
Type the following: ADNET C? <press the Enter key>.
The “?” is the COM port number the T-Max® Mgr/Pro is connected to on your computer.
Refer to the computer’s users guide to determine what serial port you are using, then use
Table 3 to determine what to type.
Table 3 - Command Lines for Loading ADNET.EXE
Serial Port Command Line Used
COM1 ADNET C1 <press Enter key>
COM2 ADNET C2 <press Enter key>
COM3 ADNET C3 <press Enter key>
COM4 ADNET C4 <press Enter key>