T-Max® Manager/Pro and T-Max® 3A User’s Guide Page 21
Table 2 - Parameter Table
Param # Description Max # Default Notes
1 Address 255 254 Address of timer
2 Beep Mode 1 0 Used for High Pressure beds. The T-Max® 3A will beep 10 seconds half
way through the session. 0=disabled, 1=Enabled.
3 Delay Time 10 0 Delay in minutes stored in the T-Max® 3A.
4 Current Sense 1 0 T-Max® Sentry™ Option. 0=Disabled, 1=Enabled.
5 Session Counts 65535 0 Total session counts for T-Max® 3As.
6 Lamp Hours 65535 0 Bulb hours for each bed.
7 Bed Hours 65535 0 How many hours a bed is on.
8 Manual Session
Counts
65535 0 Counts the # of sessions T-Max® 3A has run as a stand alone timer.
Sessions started from T-Max® Mgr or PC not counted.
9 Clean Room 1 1 0=Clean Room Disabled, 1=Enabled
10* Manual Lockout* 1 0 0=Stand Alone Enabled, 1=Disabled. Prevents the T-Max® 3A from being
an independent timer.
13 Cool Down Mode 10 0 0 = Disabled, 1-10=Enabled. Time delay in minutes allowing bed to cool.
New session cannot start until time expires.
15 Fixed Session Counts 65535 0 Counts number of sessions ran through the T-Max® 3A. This value cannot
be changed. Used as point of reference.
17 Clean Clear 1 0 0 = Press and hold the Set button for 3-4 seconds to clear the clean room.
1 = Press and release the Set button to instantly clear the clean room.
18 Redisplay 2 0 0=After a session ends and the clean room is cleared, the T-Max® 3A will
show a 0. 1=After session ends and the clean room is cleared, the T-Max®
3A will show the last session time entered. 2 = After the session ends and
the clean room is cleared, the max. time will show on the T-Max® 3A.
19 TPI 1 0 Third Party interface mode. Must be set when connecting timer to non-T-
Max® timing system.
20 External Speaker 1 0 Set to a 1 if connecting an external speaker to a T-Max® 3A. Set to 0 if
using speaker on the T-Max® 3A.
21 Pause Mode 1 0 0 = When session is paused, time will continue to count down. 1 = When
session is paused, session time will stop counting down.
22 Auto Bed Shut Off 1 0 For T-Max Intercom Systems Only. 0 = When timer is called bed will stay
on, 1 = When timer is called, bed will stuff off automatically.
* If Manual Lockout is enabled, the T-Max® 3A cannot operate as a stand-alone timer. In the event of a T-Max®
Mgr/Pro failure, this parameter cannot be enabled at the T-Max® 3A
6.3.6 Manager Utilities
Click Manager Utilities with your left mouse button. The window will appear with the
following options:
Download Program from PC to Manager
- Allows you to load the T-Max® Mgr/Pro with
new software
Edit Manager Setup
- Allows you to change T-Max® Mgr/Pro Setting for manual use.
Rescan timers
- Allows you to have the T-Max® Mgr/Pro rescan the timer network
Auto Address
- Allows you to Auto Address the entire salon.
6.3.7 Download Program from PC to Manager
Click Manager Utilities then Download Program from PC to Manager with your left mouse
button.