Specifications

Table Of Contents
T-Max® Manager/Pro and T-Max® 3A User’s Guide Page 10
Table 1 - Parameter Numbers for Getting and Sending Parameters.
Parm # Description Max # Default Notes
1 Address 255 254 Address of T-Max® 3A
2 Beep Mode 1 0 Used for High Power beds. 0=Alarm only, 1=Alarm and Flip
3 Delay Time 10 0 Delay in minutes stored in the T-Max® 3A.
4 Current Sense 1 0 For the T-Max® Sentry™ Option. 0=Disabled, 1=Enabled.
5 Session Counts 65535 0 Total session counts for T-Max® 3As.
6 Lamp Hours 65535 0 Bulb hours for each bed.
7 Bed Hours 65535 0 Number of hours a bed is on.
8 Manual Session
Counts
65535 0 Counts the number of sessions the T-Max® 3A has run while in Stand
Alone Mode
9 Clean Room 1 1 0 = Clean Room Disabled, 1 = Enabled
10* Manual Lockout 1 0 0 = Stand Alone Enabled, 1 = Disabled
13 Cool Down
Mode
10 0 0 = Disabled, 1-10=Enabled. Time delay in minutes allowing bed to
cool.
15 Fixed Session
Counts
65535 0 Counts number of sessions ran through the T-Max® 3A. This value
cannot be changed at all. Used as point of reference.
17 Clean Clear 1 0 0 = Press and hold the Up button for 3-4 seconds to clear the clean room.
1 = Press and release the Up button to clear instantly
18 Redisplay 2 0 0 = After a session ends and the clean room is cleared, the T-Max® 3A
will show a 0. 1 = After session ends and the clean room is cleared, the
T-Max® 3A will show the last session time entered. 2-10 = After the
session ends and the clean room is cleared, the max. time will show on
the T-Max® 3A.
20 External Speaker 1 0 0 = Speaker on T-Max® 3A, 1 = External Speaker will be used.
21 Pause Mode 1 o 0 = When session is paused, time will continue to count down. 1 = When
session is paused, session time will stop counting down.
22 Auto Bed Shut
Off
1 0 For T-Max Intercom Systems Only. 0 = When timer is called bed will
stay on, 1 = When timer is called, bed will stuff off automatically.
* If Manual Lockout is enabled, the T-Max® 3A cannot operate as a stand-alone timer. In the event of a T-Max®
Mgr/Pro failure, this parameter cannot be enabled at the T-Max® 3A
5.2.2 Getting and Changing Parameter Numbers
Parameters are values stored in each T-Max® 3As such as Lamp Hours, Session Counts, etc.
Table 1 shows the parameter numbers and details about them.
To get or change parameters, do the following:
1) Press the bed number you want to manipulate followed by the Enter Key. The bed number
and its status will appear.
2) Press the Call/Menu button.
3) The following message will appear: Security #. Enter the security number for level 3
followed by the enter key.
4) The following message will appear: GET PARAMS? If you just want to observe current
values, press Enter. If you want to send new values, press Next, then go to Step 6.
5) The following message will appear: WHICH PARAMETER? Enter the parameter number
from Table 1 followed by the Enter key.
The top line on the VFD display will show the bed number. The second line will show the
value for the parameter you checked.