Owner's manual

Max Machinery, Inc. G Series User Manual © Copyright 2013 Rev. 001Q4
Meter General Description
The G-Series ow metering systems are the combination
of a high pressure gear meter and a high resolution,
microprocessor based transmitter. While gear meters are
traditionally based on a design similar to a conventional
hydraulic pump, the G Series of ow meters has been
engineered to increase signal resolution, prevent internal
cavitation and greatly reduce the pressure drop required to
move uid through the gears.
The G-Series transmitter uses modern sensor technology coupled with advanced signal processing to deliver new levels
of performance and reliability. Solid state sensors are used to detect the position of a driven magnet inside the Max
Flow Meter. Changes in position are tracked by a microprocessor, which
generates an output frequency proportional to the ow rate. Advanced
signal processing provides both ne angular resolution (0.36 degrees
rotation per pulse) and rapid response (output updated every 1 ms).
The ow meter and transmitter are calibrated at the factory as a
matched set. This ensures the highest accuracy and allows for quick
setup in the eld. For eld installations where the transmitter has not
been setup with a meter at the factory, an optional serial interface kit is
available to provide
full access to all conguration options and parameters.
Flow Meter Features
Capable of operating at high pressures (425 bar/6000 psi).
Compatible with a wide range of uid types and viscosities.
Can operate at high temperatures with a suitable high
temperature transmitter.
Transmitter Features
High resolution measurement - Available in four congurations:
Frequency, Quadrature, Voltage or Current outputs.
Linearization of up to 16 points to fully describe the ow meter’s
output curve and achieve the highest system linearity over the
meter’s entire operating range.
Compensation Algorithm - Compensates for variations in Hall sensor and ow meter characteristics to provide a stable,
undamped output that accurately represents the instantaneous ow rate.
Adjustable Anti-Dither Pulse Buffer - Prevents undesired output which can occur at very low ow rates in the presence
of vibration or hydraulic noise. If the meter reverses for less than the programmed fraction of a revolution and then
resumes forward rotation, the output will represent only the total forward ow. Reverse ow which exceeds the buffered
amount will result in an output proportional to reverse ow rate.