User Manual
Max Machinery, Inc. 240 Series User Manual © Copyright 2013 Rev. 002Q4 6
Meter Specications
Model 241 242 243
1
Maximum ow rate,
Gal/min 50 140 370
Liters/min 189 540 1400
Maximum pressure, bar (psi)
Standard NPT 35, (500) 35, (500) 35, (500)
600 lb ANSI RF anges 105 (1500) 105 (1500) 105 (1500)
1500 lb ANSI RF anges --- 245 (3500) 245 (3500)
2500 lb ANSI RF anges 245 (3500) --- ---
Pressure drop, bar (PSI)
Operating maximum 10 (150) 7 (100) 5.3 (75)
Absolute maximum 21 (300) 15 (200) 10 (150)
100% ow, 3 CPS 1 (14) 0.7 (10) 0.7 (10)
2
Maximum temperature Up to 265° C (500° F)
3
Recommended ltration 150 micron
Displacement, L/Rev 0.062 0.182 0.574
Weight, Kg (Lb) 13.6 (30) 18.2 (40) 45.5 (100)
4
Typical K-Factor, (pulses/liter)
295 Transmitter 15000 5000 1500
289-700 Transmitter 403 219 58.8
Port size
NPT 1.5” 2.5” 3”
ANSI RF anges 1.5” (DN40) 2.5” (DN65) 4” (DN100)
Notes:
1
For viscosities of 3 CPS or less. Derate per pressure drop curves for higher viscosites.
2
Limited by meter seal material, transmitter model, orientation and ambient temp. See manual. Consult factory.
3
Some materials may have different lter requirements. Consult factory
4
Typical. See ow meter/transmitter calibration sheet for actual K-factor and accuracy data.