User Manual

Max Machinery, Inc. 240 Series User Manual © Copyright 2013 Rev. 002Q4 6
Meter Specications
Model 241 242 243
1
Maximum ow rate,
Gal/min 50 140 370
Liters/min 189 540 1400
Maximum pressure, bar (psi)
Standard NPT 35, (500) 35, (500) 35, (500)
600 lb ANSI RF anges 105 (1500) 105 (1500) 105 (1500)
1500 lb ANSI RF anges --- 245 (3500) 245 (3500)
2500 lb ANSI RF anges 245 (3500) --- ---
Pressure drop, bar (PSI)
Operating maximum 10 (150) 7 (100) 5.3 (75)
Absolute maximum 21 (300) 15 (200) 10 (150)
100% ow, 3 CPS 1 (14) 0.7 (10) 0.7 (10)
2
Maximum temperature Up to 265° C (500° F)
3
Recommended ltration 150 micron
Displacement, L/Rev 0.062 0.182 0.574
Weight, Kg (Lb) 13.6 (30) 18.2 (40) 45.5 (100)
4
Typical K-Factor, (pulses/liter)
295 Transmitter 15000 5000 1500
289-700 Transmitter 403 219 58.8
Port size
NPT 1.5” 2.5” 3”
ANSI RF anges 1.5” (DN40) 2.5” (DN65) 4” (DN100)
Notes:
1
For viscosities of 3 CPS or less. Derate per pressure drop curves for higher viscosites.
2
Limited by meter seal material, transmitter model, orientation and ambient temp. See manual. Consult factory.
3
Some materials may have different lter requirements. Consult factory
4
Typical. See ow meter/transmitter calibration sheet for actual K-factor and accuracy data.