User Manual

Max Machinery, Inc. 240 Series User Manual © Copyright 2013 Rev. 002Q4 15
Frequency
Single Phase
Wiring
All Other
Models
Mating Cable
Wire Color
Turck
Pin #
Case Ground Case Blue 3
Common Com Black 4
Power 5-26 Vdc V+ Brown 1
Pulse Output Ph A White 2
N/A NC Grey 5
Frequency
Single Phase
* A current sinking device produces an output pulse which is the opposite of a sourcing device.
A positive DC voltage must be applied to the wire running between PhA and your PLC. When the
output is triggered, this voltage will be grounded to zero volts. Note: use a 5k ohms resistor to limit
the current ow in the signal line.
Current Sinking* Wiring
(models 29X-6XX)
PLC
Digital
Input
V+
V+
Out
0V
Transmitter
Turck Pin #2
All Other Models Mating Cable
Wire Color
Turck
Pin #
Case Ground Case Blue 3
Common Com Black 4
Power 5-26 Vdc V+ Brown 1
Output Phase A Ph A White 2
Output Phase B Ph B Grey 5
Frequency
Quadrature
Turck Connector
Electrical Installation - Wiring
Wiring FREQUENCY
The electrical connector versions are pre-wired inside the transmitter and ready to accept a mating cable (available from
the factory). The liquid-tight, NPT models need to be wired during installation as shown in the table below:
Wiring
The 6-pin connector version is pre-wired inside the transmitter and is ready to accept a mating cable (available from the
factory). The Liquid-Tight and NPT models need to be wired during installation as shown in the table below:
NPT Models 6-Pin Connector
Circuit Board
Terminal #
Mating Cable
Wire Color
Pin #
Case Ground 1 Green A
Common 2 Black B
Power (+5-24 VDC) 3 Red C
Pulse Output 4 White D
Electrical Installation - Wiring
280 Series Transmitters