User Manual
Max Machinery, Inc. 240 Series User Manual © Copyright 2013 Rev. 002Q4 12
Meter
(Flange)
Studs Torque For Line Pressure ft-lb
(N-m)
See notes below
Absolute
Max Torque
ft-lb (N-m)
Stress at
Max Torque
(psi)*
Qty Size 500 1000 1500 2500 3500
241 (600# Flange) 4 3/4-10 24 (33) 49 (67) 73 (99) 200 (271) 47,904
241 (2500# Flange) 4 1-1/8-7 37 (50) 73 (99) 110 (149) 183 (248) 256 (247) 681 (924) 47,789
242 (600# Flange) 8 3/4-1 0 24 (33) 47 (64) 71 (96) 200 (271) 47,904
242 (1500# Flange) 8 1-8 31 (42) 63 (86) 94 (128) 157 (213) 219 (297) 483 (656) 47,822
243 (600# Flange) 8 7/8-9 53 (72) 106 (144) 159 (216) 322 (437) 47,9 72
243 (1500# Flange) 8 1-1/4-7 76 (103) 151 (205) 227 (308) 378 (513) 529 (718) 965 (1310) 47,802
240 Series ANSI Flange Stud Torque Requirements. This table shows the minimum torque required for a 2:1 tightening
factor at the indicated pressures using zinc plated studs and nuts. These values were calculated using studs with a yield
strength of Sy = 75,000 psi.
ANSI Flange Stud Torque
Notes:
Using the 241, 242 or 243 meters at pressures greater than 500 psi
will require anges
. Max has bolt kits available for
ange installations.
For unplated non-lubricated nuts and studs, multiply the above torque by 1.5.
For lubricated nuts and studs, multiply the above torque by 0.9.
For cadmium plated nuts and studs, multiply the above torque by 0.8.
*Stress in bolt calculated for thread root diameter.