Page 10 220-000-350 © 2004 Max Machinery, Inc.
221 Series Gear Flowmeters — Linearity
S
ERIES
221 L
INEARITY
:
Typical Linearity (at various viscosities)
(This Flowmeter is generally used for 100 CPS or greater viscosities.)
Maximum Error: -7.5 cc/min. or 0.75%
Typical Flowmeter Specifications
Displacement: 23.5 cc/rev
Pulses/CC with 284-XXX Transmitter: 4.26
Maximum Pressure: 1500 PSI standard
3000 PSI High Pressure
Discontinued