User guide
Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 19
216 Piston Flow Meter
MODEL 216 WITH INDUSTRIAL
HOUSING TRANSMITTER
EX-PROOF HOUSING
TOP VIEW
not to scale
2.26”
(57mm)
2.26”
(57mm)
0.65”
(17mm)
4.825”
(123mm)
8.94”
(227mm)
mounting holes
3/8”-16NC
(6) places
in out
BOTTOM VIEW
9.5 SQ”
(241mm)
3.00”
(76mm)
1.93”
(49mm)
MODEL 216 WITH EX-PROOF
HOUSING TRANSMITTER
9.45”
(240mm)
5.39”
(137mm)
2.26”
(57mm)
1/2”
FNPT
3.0”
(76mm)
7.0 SQ”
(178mm)
^t
1
0
0
0
c
p
s
3
c
p
s
1
0
0
c
p
s
3
0
0
c
p
s
Flow Rate (L/min)
0
30
35
5
10
15
20
25
TYPICAL PRESSURE DROP (Delta P versus Flow rate for various viscosities)
0.1 0.2 0.3 0.5 1 2 3 5 10 20 30 50
100
—2 bar
—1.5 bar
—0.5 bar
Intermittent Duty Area
Expected Failure Area
Continuous Duty Area
3
0
0
0
c
p
s
Pressure Drop (psi)