User guide
Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 18
215 Piston Flow Meter
Flow Rate (cc/min)
Pressure Drop (psi)
0
30
35
5
10
15
20
25
TYPICAL PRESSURE DROP (Delta P versus Flow rate for various viscosities)
30 50 100 200 300 500 1000 2k 3k 5k
10k 20k 30k 50k
—2 bar
—1.5 bar
—1 bar
—0.5 bar
Intermittent Duty Area
Expected Failure Area
Continuous Duty Area
3
0
0
c
P
3
0
0
0
c
P
1
0
0
0
c
P
1
0
0
c
P
3
c
P
MODEL 215 WITH INDUSTRIAL
HOUSING TRANSMITTER
MODEL 215 WITH EX-PROOF
HOUSING TRANSMITTER
EX-PROOF HOUSING
TOP VIEW
not to scale
2.26”
(57mm)
2.26”
(57mm)
0.65”
(17mm)
1.93”
(49mm)
7.48”
(190mm)
3.93”
(100mm)
2.26”
(57mm)
1/2”
FNPT
7.99”
(203mm)
3.93”
(100mm)
mounting holes
5/16-18NC
(6) places
2.0”
(51mm)
BOTTOM VIEWBOTTOM VIEW
in out
7.88 SQ”
(200mm)
2.125”
(54mm)
4.95 SQ”
(125mm)