User guide

Max Machinery, Inc. 210 Series User Manual © Copyright 2013 Rev. 002Q4 17
214 Piston Flow Meter
3
c
P
Expected Failure Area
Continuous Duty Area
Intermittent Duty Area
3
0
0
0
c
P
  
1
0
0
0
c
P
3
0
c
P
Flow Rate (cc/min)
Pressure Drop (psi)
0
30
35
5
10
15
20
25
TYPICAL PRESSURE DROP (Delta P versus Flow rate for various viscosities)
10 20 30 50 100
200 300 500 1000 2k 3k 5k
10k
—0.5 bar
—1 bar
—1.5 bar
2 bar
1
0
0
c
P
  
3
0
0
c
P
4.875 SQ”
(124mm)
BOTTOM VIEW
MODEL 214 WITH INDUSTRIAL
HOUSING TRANSMITTER
MODEL 214 WITH EX-PROOF
HOUSING TRANSMITTER
EX-PROOF HOUSING
TOP VIEW
not to scale
2.26”
(57mm)
2.26”
(57mm)
0.65”
(17mm)
1.93”
(49mm)
6.3”
(160mm)
2.57”
(65mm)
2.26”
(57mm)
6.61”
(168mm)
2.57”
(65mm)
in out
3.00 SQ”
(76mm)
1/2”
FNPT
mounting holes
1/4-20NC
(6) places
1.125”
(29mm)
2.125”
(54mm)