120-200-350 © 1993 (Rev 5/97) Max Machinery, Inc. Page 25
Command Response Description
Q22 A22 a Query Totalizer Pulse Output Speed
where a = 0 - No Pulse
= 1 - Pulse Fast
= 2 - Pulse Medium
= 3 - Pulse Slow
L23 aaaa A Load Totalizer Output Time
where aaaa = Output Time
Q23 A23 aaaa Query Totalizer Output Time
where aaaa = Output Time
L24 a A Load Totalizer Reset Key Function
where a = Reset Key Function
= 0 - No Function
= 1 - Reset Totalizer
= 2 - Unlatch Output
= 3 - Reset and Unlatch
Q24 A24 a Query Totalizer Reset Key Function
where a = Reset Key Function
= 0 - No Function
= 1 - Reset Totalizer
= 2 - Unlatch Output
= 3 - Reset and Unlatch
L25 a A Load Totalizer D.P. Location
where a = 0 - No Dec. Pt.
= 1 - XXXXXXXXX.X
= 2 - XXXXXXXX.XX
= 3 - XXXXXXX.XXX
= 4 - XXXXXX.XXXX
= 5 - XXXXX.XXXXX
Q25 A25 a Query Totalizer D.P. Location
where a = 0 - No Dec. Pt.
= 1 - XXXXXXXXX.X
= 2 - XXXXXXXX.XX
= 3 - XXXXXXX.XXX
= 4 - XXXXXX.XXXX
= 5 - XXXXX.XXXXX
L31 aa A Load Rate meter Smoothing
where aa = Smoothing Fact. (05 - 75)
(Must be in steps of 5)
Q31 A31 aa Query Rate meter Smoothing
where aa = Smoothing Factor
RS-485 SERIAL COMMANDS