Installation Guide

21
STEP 14
LIFT REMOVAL
STEP 15
RE-INSTALLATION
1. Depress the lowering valve on the power unit.
2. Ensure that the lift is lowered all the way to the ground and hydraulic pressure is relieved.
3. Disconnect the power unit from the power source and / or ensure that the power to the circuit is shut o󰀨 to prevent
accidental powering on of the lift while disassembling.
4. With a cloth in hand to collect weaping uid, disconnect the cylinder hoses from the cylinder. Hoses can be coiled
and stored on the power unit cart.
Before removing cylinder hoses, always ensure that the hydraulic pressure has been relieved from the system by
depressing the lowering valve until the lift is fully lowered or the raised load is fully settled onto the safety lock blocks.
Never connect or disconnect hoses with the lift in an elevated position.
Do not perform any maintenance or installation of any components with out rst ensuring that electrical power has been
disconnected at the source or panel and cannot be re-energized until all maintenance and/or installation
procedures are completed.
5. Be careful to clean up any spilled hydraulic uid that may drip from the hose assemblies.
6. Remove the lift arm assemblies.
7. Loosen the anchor bolts. Be careful not to disturb the lift column until ready to move the column.
8. Move the column to your storage area. Secure with straps or other device to prevent any accidental tipping or
movement of the columns during storage.
1. Clear installation area of debris, tools and equipment.
2. Blow out the mounting holes with compressed air or clean with a nylon brush.
3. Inspect the drop in anchors for proper setting and the concrete for defects and / or damage.
4. Line up the holes of the Base Plates with the anchors. Re-shim the lift as required to ensure the lift is installed
level.
5. With the Shims and Anchor Bolts in place, tighten all Anchor Bolts tight to the base plate. DO NOT USE AN
IMPACT WRENCH FOR THIS PROCEDURE.
6. Follow all procedures as outlined in Steps 8 - 12.
Inspect all drop in anchors for proper setting and or damage each time the lift is re-installed. Inspect the concrete for
cracks defects and/or damage. Do not reinstall the lift if any of the drop in anchors are defective or the concrete is
cracked or defective.
The lift must be re-leveled, shimmed and bled each time the lift is reinstalled. Failure to do so may result in injury or
death.