User manual
Preliminary MAVIX
- 38 -
Figure 17: StreamR:
Recording Schedules
Configuration
Refresh
This will recopy the configuration file (Comfig.mdb) to local
application path, and any changes in the configuration relevant to
current user, will be immediately reflected, (such as addition \removal
of cameras). The user is presented with a dialog displaying the current
known location of the configuration file, (as kept in the system
registry), the user may browse for a new location, or simply click the
OK button to import the Config.mdb file from its current original
location.
A user who wishes to change the default settings, may repeat the steps described
above for any camera on the list.
MAIN WINDOW
Closing the main setup window, will bring us to the main (and only) recording
window, in which every camera is represented by a small square shape label, in this
version there are 120 squares indexed from 1 to 120, the color of the square indicates
the current status of the camera it represents.
RED – currently recording.
GREEN – Active, but Idle.
YELLOW - Error.
At the bottom of the window, the free available disk space is displayed in units of
Gigabytes , when the free disk space of the recording drives drops below 500
Megabytes (0.5 Giga), the recorder automatically starts deleting old AVI files to free
disk space. Those deleted AVI files will no longer be available for display by the
Maview player application.