User manual
Preliminary MAVIX
- 14 -
Bit Rate (MR100 type): 1000 to 2000 bps.
Bit Rate (MR150 type): 10 to 4000 bps.
Note: These parameters are defined for the selected camera unit ONLY.
The user may check the validity of the parameters by either
viewing the resulting video picture at the video window
(Desktop Player), or by performing a “Connect” command to
connect a Camera from list A to a Unit with a monitor on list
B. The connection status Connected/Disconnected is displayed
at the bottom of the form.
2. AUDIO: The Audio Configure & Test window allows the user to control
and adjust the microphone and speakerphone volumes for each
unit. It is possible to connect a Microphone from a unit on list
A(B) to a Speaker from a unit on List B(A). The connection
status Connected/Disconnected is displayed at the bottom of the
form.
3. RS232: In the Serial Port window, the user may define the connection
parameters for both COM1 (RS-232) and
COM2 (RS232/RS485 Jumper selectable)
ports. The parameters defined include the
BAUD rate, number of data bits, stop bits,
parity and flow control. The connection
status Connected/Disconnected is displayed
at the bottom of the form.