4.2 Cable Connections
The AP requires power and an Ethernet connection. These can be provided discretely from
a power adaptor (as supplied) and a standard CAT5 Ethernet cable or with a single
Ethernet cable carrying PoE+.
Two power supply modules are available from ip.access, designed for use with the
ip.access E61 AP, that are compliant with the IEEE 802.3at standard:
Direct power from the supplied mains power adapter
Optionally, a PoE+ injector, commonly used for single site installations, which must
be ordered separately
Alternatively, power the E61 AP from a PoE+ switch.
4.2.1 PSU and LAN
When a suitable PSU is used to power the AP the PoE+ injector unit is not needed.
However, this means that a mains socket providing power to the AP must be within reach of
the cabling included with the PSU. This is typically about 1.5m. The PSU for the E61 AP is
supplied as standard.
12V PSU
Mains
Input
LAN Cable to nearest switch/gateway
(max 100m)
12V DC
Cable to AP
(Approx 1.5m)