Installation Instructions

Table Of Contents
nanoLTE E61 AP Hardware Installation nanoLTE E61 AP Commissioning
NANO_INST_43325 v205_0.6 for N4G_2.5 © ip.access Limited 2019 Page 16
3.4 Access the Commissioning Web Page for the LTE AP
The commissioning web page is only accessible after performing a factory reset. The login
prompt for this web page is available for 10 minutes, after which the LTE AP will attempt to
boot normally.
1) Plug an Ethernet cable into the AP that is connected to a network that allows the
AP to connect to the Internet.
2) Plug in the power supply unit that is in the box with the AP to a mains outlet and
the AP. The AP will start up.
3) Perform a factory reset on the LTE AP:
Press and hold the LTE AP reset button for at least 5 seconds, then release
the reset button.
The LTE power LED will briefly turn red as the AP reboots, and will then
return to green.
Note: See section 5.3 for more information about factory reset.
4) Make a note of the time that the factory reset was started. The login prompt for the
web commissioning page will start to be available after the AP has contacted the
Redirector and re-downloaded its OLM Package. From this point, the login prompt
will be available for 10 minutes.
5) During this interval, start a web browser on the commissioning terminal.
6) After 10 minutes from starting the factory reset, swap the AP to the Ethernet cable
that connects it directly to the commissioning terminal.
7) In the address bar of the web browser on the commissioning terminal, type in the
pre-defined static IP address and port number for the web server on the AP and
press <Enter>:
http://192.168.0.10:8089
8) A login screen should appear in the browser. If the login screen does not appear
immediately, refresh the browser screen once every 20 seconds until it appears.