Installation Instructions
Table Of Contents
- nanoLTE E61 AP Hardware Installation
- Table of Contents
- 1 Introduction
- 2 Installation Overview and Requirements
- 3 nanoLTE E61 AP Commissioning
- 3.1 Requirements for Commissioning with the Web Page
- 3.2 Redirector First Contact and NTP Synchronisation for Software Update
- 3.3 Configure a Commissioning Terminal
- 3.4 Access the Commissioning Web Page for the LTE AP
- 3.5 Optional - Software Download
- 3.6 Configure the Connection to the NOS Server
- 3.7 Commissioning Complete
- 4 nanoLTE E61 AP Hardware Installation
- 5 Troubleshooting
- 6 AP and PSU Regulatory Information
nanoLTE E61 AP Hardware Installation Installation Overview and Requirements
NANO_INST_43325 v205_0.6 for N4G_2.5 © ip.access Limited 2019 Page 6
Port Usage Without IPsec
Without IPsec, the following ports are used:
This assumes the AP is on a secure network that does not need IPsec. For example, a
self-contained test network.
Protocol Destination Port Use
sctp 36412 SCTP connection
udp 2152 GTP to/from AP
tcp 8080 or 7547 TR-069 to the NOS (the NOS listens for TR-069
connections on both ports)
tcp 80 PM upload, software download, CRL download, AP
diag upload