Installation Instructions

Table Of Contents
nanoLTE E61 AP Hardware Installation Installation Overview and Requirements
NANO_INST_43325 v205_0.6 for N4G_2.5 © ip.access Limited 2019 Page 5
AP in Commissioning Mode
When the AP is in commissioning mode after a factory reset, this is the only time that the
AP allows an inbound connection. The LTE AP takes the fixed IP address 192.168.0.10.
The AP then listens for an incoming connection to the commissioning web page:
Note: The commissioning web page is only available if the LTE AP’s DOCP (obtained from the
Redirector) indicates that the LTE AP should enable the web page.
Port Usage With IPsec
With IPsec, the standard two ports are used:
The AP will need to continue using these ports:
If the NOS is configured for HTTPS access to the Certificate Validation Service for CRL
Mirror server functionality, the AP will also need to use this port outside of the IPsec tunnel:
Protocol Destination Port Use
tcp 8089 Commissioning web page
Protocol Destination Port Use
udp 500 IPSec initial connection
udp 4500 IPSec operations
Protocol Destination Port Use
udp 53 DNS
udp 123 NTP
Protocol Destination Port Use
tcp 443 HTTPS for CRL download from the NOS