Technical data
5
MAVEA LLC recommends that the fi lter system not be left unused for a long period. If the
PURITY C fi lter system is not used for several days (2–3 days), we recommend that the fi lter system
be fl ushed with the fl ushing volume X indicated in the table below. After periods of non-use of over
4 weeks, the fi lter should be fl ushed with fl ushing volume Y or else replaced. Please also note that
the maximum usage period of the fi lter cartridge is 12 months (Chapter 6).
Filter cartridge Flushing volume X
after 2–3 days non-use
Flushing volume Y
after 4 weeks non-use
PURITY C50 Quell ST 2 liters (0.5 US gallons) 20 liters (5.3 US gallons)
PURITY C150 Quell ST 3 liters (0.8 US gallons) 30 liters (7.9 US gallons)
PURITY C300 Quell ST 6 liters (1.6 US gallons) 60 liters (15.9 US gallons)
The fi lter system must not be opened or dismantled during operation. The fi lter cartridge must •
not be opened.
The fi lter system fi lter head is designed for a service life of 10 years counted from the date of •
installation. It must be replaced after 10 years.
Production date•
Production code fi lter head – example: H 8252 11882
8 Production year, here: 2008
25 Production week, here: calendar week 25
2 Production day from Monday (1) to Friday (5), here: Tuesday
11882 Consecutive identifi cation number
Production code fi lter cartridge – example: B8252080010
8 Production year, here: 2008
25 Production week, here: calendar week 25
2 Production day from Monday (1) to Friday (5), here: Tuesday
08 Batch No. fi lter medium, here in terms of quantity the eighth batch used
0010 Consecutive number of the fi lter cartridge, here the tenth cartridge; reset when the day changes
3.5 Technical Safety Assembly Instructions
The terminal equipment operated with the fi lter must be free of limescale prior to installation.•
Protect the fi lter system from sunlight and mechanical damage. Do not assemble near sources •
of heat and open fl ames.
A stop valve must be installed before the fi lter system intake hose.•
If the water pressure is higher than 8.6 bar (125 psi), a pressure reducer must be installed in •
front of the fi lter system.
The fi lter head may be connected to the mains only with a non-return valve according to •
EN 13959 or higher quality protection against return fl ows (see Chapter 10).
No copper pipes and no galvanized or nickel-plated pipes/connectors may be installed between •
the water fi lter and consumer. When choosing the material for parts that come into contact with
water after the MAVEA fi lter system it must be remembered that, due to the process, decar-
bonized water contains free carbon dioxide.
All parts must be installed in accordance with the country-specifi c requirements on the installa-•
tion of drinking water facilities.
4 Installation
!
Caution: Prior to installation, read the Technical Data (Chapter 9) and the Operating and Safety
Information (Chapter 3). After storage and transport below 0°C (32°F) the product must be stored in
the open original packaging for at least 24 hours at the stated ambient temperatures (Chapter 9) for
operation.
1001411-001_1001426-001.indd Abs1:51001411-001_1001426-001.indd Abs1:5 02.03.2009 16:41:29 Uhr02.03.2009 16:41:29 Uhr