PURITY C Water Filter System Manual 1 2 3 4 5 6 7 8 9 10 1001411-001_1001426-001.indd Abs1:1 Definition of Terms General Information Operating and Safety Information Installation Exchanging the Filter Cartridge By-Pass and Capacity Tables Repair Troubleshooting Technical Data Order Numbers 02.03.
8 3 10 4 2 1 5 7 9 6 Out In 2 1001411-001_1001426-001.indd Abs1:2 02.03.
1 Definition of Terms All filter head types: 1 Filter head 2 Locking handle 3 Water outlet 3/8" – 18 NPT 4 Water inlet 3/8" – 18 NPT 5 Wall mount 6 Filter cartridge 7 Protective cap 8 Flush valve 9 Flush hose Additional for filter head types PURITY C 0–70%: 10 By-pass setting 2 General Information 2.
2.3 Storage/Transport Adhere to the ambient conditions in the Technical Data (Chapter 9) for storage and transport. The handbook should be retained for use with the product, kept for the whole service life of the filter system and passed on to subsequent owners. 2.4 Recycling/Disposal By disposing of this product and its packaging in the correct manner you are helping to prevent potential negative impacts on people and the environment that could be caused by incorrect disposal.
MAVEA LLC recommends that the filter system not be left unused for a long period. If the PURITY C filter system is not used for several days (2–3 days), we recommend that the filter system be flushed with the flushing volume X indicated in the table below. After periods of non-use of over 4 weeks, the filter should be flushed with flushing volume Y or else replaced. Please also note that the maximum usage period of the filter cartridge is 12 months (Chapter 6).
4.1 Assembling the Filter Head, Water Connection ! Caution: Ensure that the locking handle on the head is open. • Close water intake and switch off power supply to the terminal equipment. A • Fit the wall mount 5 at the intended position. ! Caution: During assembly, note the installation dimensions, bending radii of the B hoses and dimensions of the accessories. The system can be operated vertically and horizontally.
cartridge must be stored in the open original packaging for at least 24 hours at the stated ambient temperatures (Chapter 9) for operation. Note: When the locking handle is open, the water supply to the cartridge is interrupted and shortcircuit operation with direct water flow from the water inlet 4 to the outlet 3 is possible (if necessary, close the water supply and switch off the power supply to the downstream appliance). • Open locking handle 2 .
Combi Ovens and Conventional Ovens German carbonate hardness °dH 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 Grains per US gallon By-pass setting 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% 10% PURITY C50 Quell ST Liters US gallons 1000 800 600 550 500 450 400 370 340 310 290 270 250 230 22
German carbonate hardness °dH 24 25 26 27 28 29 30 31 32 33 34 35 Grains per US gallon By-pass setting 24 25 26 27 28 29 30 31 32 33 34 35 30% 30% 30% 30% 30% 30% 30% 30% 30% 30% 30% 30% PURITY C50 Quell ST Liters US gallons 210 200 190 180 175 170 165 160 155 150 145 140 55 53 50 48 46 45 44 42 41 40 38 37 Filter capacity PURITY C150 Quell ST Liters US gallons 620 600 580 560 540 520 500 480 460 450 440 430 164 159 153 148 143 137 132 127 122 119 116 114 PURITY C300 Quell ST Liters US gallons 1200
8.2 No or low water flow in spite of open water intake Cause: Mains pressure too low. Troubleshooting: Check mains pressure. If the fault continues, check the filter system and filter cartridge and change if necessary. Cause: Troubleshooting: 8.3 Leak Cause: Troubleshooting: Filter head not mounted in direction of flow. Dismantle filter head and install in direction of flow (Chapter 4). Screwed connections not fitted correctly. Check mains pressure.
10 Order Numbers PURITY C Filter System Article Article Description PURITY C 30% 3/8" NPT filter head, pack of 20 Filter head with 30% by-pass (3/8" – 18 NPT connection) Filter head with 30% by-pass (3/8" – 18 NPT connection) Filter head with variable by-pass 0–70% (3/8" – 18 NPT connection) Filter head with variable by-pass 0–70% (3/8" – 18 NPT connection) PURITY C 30% 3/8" NPT filter head, pack of 3 PURITY C 0–70% 3/8" NPT filter head, pack of 20 PURITY C 0–70% 3/8" NPT filter head, pack of 3 PURITY C
PN: 1001411-001 / 1001426-001 MAVEA LLC 675 Tollgate Road, Suite G Elgin, IL 60123 USA www.mavea.com info@mavea.com Information in the instruction for use subject to change 1001411-001_1001426-001.indd Abs1:12 02.03.