7.2 No or low water fl ow in spite of open water intake
Cause: Mains pressure too low.
Troubleshooting: Check mains pressure. If the fault continues, check the fi lter system and fi lter
cartridge and change if necessary.
!
Caution: Prior to changing, read the Technical Data (Chapter 10, system handbook PURITY
Quell ST Water Filter System) and the Operating and Safety Information (Chapter 3, system hand-
book PURITY Quell ST Water Filter System).
7.3 Leak at Screwed Connections
Cause: Screwed connections not fi tted correctly.
Troubleshooting: Check mains pressure. Check all screwed connections and mount according to
Chapter 4.2, system handbook PURITY Quell ST Water Filter System.
If the fault continues, exchange fi lter system.
!
Caution: Prior to changing, read the Technical Data (Chapter 10, system handbook PURITY
Quell ST Water Filter System) and the Operating and Safety Information (Chapter 3, system hand-
book PURITY Quell ST Water Filter System).
7.4 Leak after Filter Replacement
Cause: O-ring at the fi lter cartridge is not seated correctly.
Troubleshooting: Check correct seat of the O-ring (Chapter 4.3, system handbook PURITY Quell ST
Water Filter System).
!
Caution: Prior to changing, read the Technical Data (Chapter 10, system handbook PURITY
Quell ST Water Filter System) and the Operating and Safety Information (Chapter 3, system hand-
book PURITY Quell ST Water Filter System).
7.5 No Display Function
Cause: Battery drained.
Troubleshooting: Replace display unit (Order number see Chapter 11, system handbook PURITY
Quell ST Water Filter System).
Note: When replacing the display unit, follow the enclosed Manual.
7.6 Data in Display Flashing
Cause: Monthly limit expired or the remaining capacity of the fi lter cartridge is exhausted
(Chapter 3.2).
Troubleshooting: Replace fi lter cartridge (Chapter 4).
7.7 By-pass setting in the display does not agree with the setting of the by-pass screw
(cf. 7.8/7.9)
Cause: Filter was not commissioned correctly.
Troubleshooting: Flush fi lter again (Chapter 3.4). Check data in the display after fl ushing
(Chapter 3.5).
7.8 By-pass setting in the display does not agree with the setting of the by-pass screw
(cf. 7.7/7.9 )
Cause: Flow rate too high.
Troubleshooting: Slightly open fl ush valve during fl ushing.
!
Caution: Don‘t forget the bucket! Flush fi lter again (Chapter 3.4). Check data in the display after
fl ushing (Chapter 3.5).