Technical data
13
Program Overview
ID-Information
ÀÀÀ
00 Current level
ÀÀÀ
-1  History level 1
ÀÀÀ
-2  History level 2
ÀÀÀ
-3  History level 3
ÀÀÀ
-4  History level 4
ÀÀÀ
E1  Error inlet metre
ÀÀÀ
E2  Error drainage metre
Temporary hardness  set of 2 sec.
ÀÀÀ
Device type  set of 2 sec.
ÀÀÀ
RESET  set of 2 sec.
ÀÀÀ
Parameter acceptance
ÀÀÀ
Month limit  set of 2 sec.
ÀÀÀ
Hardness type  set of 2 sec.
Operating mode
ParameterisationRetrieval mode
1 x button Press button 4 seconds
30 sec. no acitivity
no Parameter acceptance 
20 sec. no activity
Temporary hardness • 
Capacity • By-pass • 
last fi lter change data
7 Troubleshooting
7.1 No water fl ow
7.1.1 Cause: Water intake closed.
Troubleshooting: Open water intake on the upstream stop valve or inlet valve on inlet hose.
7.1.2 Cause: Confused inlet and outlet installation.
Troubleshooting: Check and, if necessary, correct the assembly situation (Chapter 4.3, system hand-
book PURITY Quell ST Water Filter System) of the intake hose 
6
 with intake valve 
7
 and terminal 
device connection 
8
 with fl ush valve 
9
. Pay attention to the direction of fl ow according to the 
arrows on the connector head 
4
.
7.1.3 Cause: Non-return valve in the entrance to the connector head not seated correctly.
Troubleshooting: Check direction of fl ow as in Chapter 7.1.2 and seat of the non-return valve and cor-
rect if necessary (Chapter 4.3, system handbook PURITY Quell ST Water Filter System). Flush fi lter 
system again (Chapter 3.4).
!
 Caution: The following faults may be remedied only by trained or authorised personnel.