Technical data
10
4.2 Inserting the Filter Cartridge
Place new fi lter cartridge •
2
in the pressure vessel
1
.
Check the connector seat of the fi lter cartrigde O-ring in the pressure vessel •
lid
3
for dirt and damage.
Check the O-ring seal of the fi lter cartridge •
2
for correct seat in the groove,
and for dirt and damage.
Stand on the kick loops •
12
.
Lift the pressure vessel •
1
and turn clockwise until the mantle handles
16
are
over the kick loops
12
.
Note: The cartridge seat has been lubricated with food-safe lubricant at the factory.
Stand on the kick loops •
12
.
Place the pressure vessel lid •
3
in the position “INSERT“ on the pressure vessel
1
with the
lock
15
in the appropriate groove.
Press the pressure vessel lid •
3
down and turn clockwise until it engages.
Switch on power supply to the terminal device (plug).•
To fl ush/drain the fi lter systems with and without a measuring and display unit carry out the steps
described under Chapter 3.4 to commission the new fi lter cartridge.
5 Repair
Regularly check the fi lter system for leaks. Regularly check the hoses for kinks. Bent hoses must be
replaced.
The complete fi lter system must be replaced in rotation after 10 years.
The hoses must be replaced in rotation after 5 years.
!
Caution: Prior to changing, read the Technical Data (Chapter 10, system handbook PURITY
Quell ST Water Filter System) and the Operating and Safety Information (Chapter 3, system hand-
book PURITY Quell ST Water Filter System).
Regularly clean the outside of the fi lter system with a soft, damp cloth.
!
Caution: Do not use any substances incompatible with the material (Chapter 3, system hand-
book PURITY Quell ST Water Filter System) or abrasive cleaning materials.
6 Query Mode
The following data can be queried in the query mode: