5. HANGING THE FAN
REMEMBER to turn off the power. Follow the steps
below to hang your fan properly.
1. Remove the decorative canopy bottom cover from
the canopy by turning the cover counter clockwise.
(Fig. 5)
2. Remove the hanger bracket from the canopy by
removing the 1 of 2 screws from the bottom of the
hanger bracket and loosening the other one a half
turn from the screw head. Next, turn the canopy
counter clockwise to removing the hanger bracket
from the canopy. (Fig. 5)
3. Secure the hanger bracket to the ceiling outlet box
using screws and washers included with your outlet
box. (Fig. 6)
4. Loosen the two set screws and remove the hitch
pin and lock pin from the central shaft/top coupling of
the motor assembly. Doing so will allow the down rod
to enter the central shaft. (Fig. 7)
5. Route wires exiting from the top of the fan motor
through the coupling cover, canopy cover and canopy
and then through the ball/downrod. (Fig. 7)
6. Align the holes at the bottom of the downrod with
the holes in the collar on top of the motor housing.
Carefully insert the hitch pin through the holes in the
collar and downrod. Be careful not to jam the pin
against the wiring inside the downrod. Insert the lock
pin through the hole near the end of the hitch pin until
it snaps into its locked position. (Fig. 7)
WARNING/CAUTION: Failure to properly install lock
pin as noted in step 6 could result in fan loosening
and possibly falling.
7. Tighten two set screws on top of the fan motor
firmly.
8. Now lift the motor assembly into position and place
the hanger ball into the hanger bracket. Rotate down
rod until the "Check Tab" has dropped into the
"Registration Slot" and the down rod and ball
assembly seat firmly. The down rod and ball
assembly should not rotate if this is done correctly.
(Fig. 8)
9. Attach the lag bolt and flat washer to ceiling joist.
Attach the safety cable to lag bolt. Slide cable clamp
onto safety cable (from fan). Place the end of cable
through the lag bolt. Pull as much cable through lag
bolt as possible. Feed end of cable into clamp hole
and firmly tighten screw (Fig. 8). Cut off excess
safety cable.
Figure 7
Figure 8
Tab
UL Listed
electrical
box
Hanger bracket
Supply wires
Downrod
Coupling cover
Canopy
Canopy cover
Set screws
Hitch pin
Lock pin
Mounting screws
(supplied with
electrical box)
Registration
slot
Screw
Safety cable
Safety cable
clamp