Owner Manual

The results are only valid for the tested sample(s).
This report may only be copied or reprinted in its entity, parts of it only with a written acceptance by Eurofins.
392-2017-00132101_H_EN Page 3 of 11
3 Applied Test Methods
3.1 General Test References
Regulation, protocol or
standard
Version
Reporting limit
VOC [µg/m³]
Calculation of TVOC
Combined
uncertainty
¤
[RSD(%)]
CEN/TS 16516 October 2013 5 Toluene equivalents 22%
ISO 16000 -3 -6 -9 -11 2006-2011 depending on part 2 Toluene equivalents 22%
ASTM D5116 2010 - - -
CDPH
CDPH/EHLB/Standard Method
V1.2. (January 2017)
2 Toluene equivalents 22%
3.2 Specific Laboratory Sampling and Analyses
Procedure External Method Internal SOP
Quantification
limit / sampling
volume
Analytical
principle
Uncertainty
¤
[RSD(%)]
Sample preparation
ISO 16000-11:2006,
EN16402:2013, CDPH,
AgBB/DIBt, EMICODE
71M549810 - - -
VOC emission chamber
testing
ISO 16000-9:2006,
CEN/TS 16516:2013
71M549811 -
Chamber and air
control
-
Sampling of VOC
ISO 16000-6:2011,
CEN/TS 16516:2013
71M549812 5 L Tenax TA -
Analysis of VOC
ISO 16000-6:2011,
CEN/TS 16516:2013
71M542808B 1 µg/m³ ATD-GC/MS 10%
Sampling of aldehydes
ISO 16000-3:2011,
CEN/TS 16516:2013
71M549812 35 L DNPH -
Analysis of aldehydes
ISO 16000-3:2011, EN
717-1, CEN/TS
16516:2013
71M548400 3-6 µg/m³ HPLC-UV 10%