Specifications

Specifications 53
Trigger input signal (opto-isolated):
- Termination: 511 series.
- Input current:
Min of low: 0 µA.
Max of low: 250 µA.
Min of high: 5 mA
1
.
Max of high: 15 mA
2
.
- Input voltage:
Min of low: 0 V.
Max of low: 0.8 V.
Min of high: 2 V.
Max of high: 5 V.
Environmental
Min./max. ambient operating temperature: 0°C - 55° C.
Min./max. storage temperature: -40° C - 75° C.
Max. altitude for operation: 3000 meters.
Max. altitude for transport: 12000 meters.
Operating humidity: 20 - 80% relative humidity (non-condensing).
1. A Min of 6.3 mA recommended.
2. A Max of 10 mA recommended.