Specifications

Specifications 51
Specifications
Electrical
Input signals in RS-422 format (if available):
- Termination: 100 .
- Input voltage:
Differential range: 200 mV to 14 V.
Common mode range: -7 V to 7 V.
Output signals in RS-422 format (if available):
- Specified for a 100 load.
- Output voltage:
Differential range: 2 V to 5 V.
Common mode range: 1.5 V to 3 V.
Form Factor Operating Voltage and current
Power Consumption
1
5V ±5% -5V ±5% 3.3V ±5% 12V ±10% -12V ±10%
PCI 1.0 A n/a n/a 150 mA 75 mA 7.7 W
PC/104-Plus 140mA 60mA 1.03A 15mA n/a 5.08W
1
This number represents the total power consumption of the Matrox Meteor-II board only. It does not include the power consumption of a camera which
draws current through the auxiliary power supply input.