3. SETU ATA211 will send all the RTP packets with RTP QoS setting, enter the RTP DiffServe/ ToS as per
your requirement. Valid range is from 00-63, Default: 46
4. MAC address selection provides you two options: Unique and Clone. Default: Unique MAC Address.
If you select Unique MAC Address, the system will use the unique MAC address assigned to it as source
MAC address on all Ethernet frames.
Select Clone MAC Address, if you want the system to use MAC address other than unique MAC address.
If you select Clone MAC Address, enter the desired MAC address manually in the Clone MAC Address
field. MAC address is in hexadecimal format, e.g. 00:50:c2:55:b0:10.
5. SETU ATA211 has an embedded web server called Jeeves, for system configuration. You may change the
Web Server Port as per your requirement. Valid range of the port is: 80, 1024-65535. Default: 80
6. SETU ATA211 has an embedded FTP server for Software Upgrade. You may change the FTP Server
Port as per your requirement. Valid range is 21, 1024-65535.Default: 21
7. After you have set all the parameters as per your requirement, click Submit at the bottom of the page.
8. You will get a prompt, 'This will restart the system, do you want to continue?'
9. Click OK to save the settings.
The system will restart.