Specifications

Matrix SETU ATA211 System Manual 39
Route to FXS. If not answered within ring timer, answer the call, collect number & route as per
incoming call route selection: The system will place the incoming call on the FXO port to the FXS
port. The phone connected to the FXS port will start ringing for the duration of the Ring Timer (default:
45 seconds). If the call is not answered within the timer, ATA answers the call and gives dial tone to the
caller. When the caller dials the number, the system collects the digits and routes the call as per the
Incoming Call Route you select: SIP1, SIP2, SIP3 or Dialed Number Table.
If you select this option, select the Incoming Call Route. You may also configure the Ring Timer.
2. Enter the Fixed Destination Number in this field, if the incoming call routing option requires the call to be
finally placed to a fixed destination. You can configure the fixed destination number of maximum 40
characters. Default: Blank
3. You need to configure this parameter, only when the Incoming Call Routing option you selected requires
the Incoming Call Route to be selected. You can select:
SIP1/SIP2/SIP3: Select SIP1/SIP2/SIP3 as the Incoming Call Route, if you want to route the incoming
call received on FXO port using SIP1/SIP2/SIP3 trunk.
Dialed Number Table: Select option as Incoming Call Route, if you want ATA to route the incoming
call on the basis of the ‘number’ dialed. ATA will match the dialed number with the Dialed Number
Table. If the number matches, the destination route corresponding to the number will be used for call
routing. If you select this option, you must configure the Dialed Number Table.
To do this,
Click the arrow icon. The Dialed Number Table opens in a new window.