Specifications

24
8.5 ERROR MESSAGE TROUBLESHOOTING
ERROR MESSAGE 0x0044
1) CAUSE - Actual speed is higher than commanded speed by limit and is increasing.
2) SOLUTION
a. Press and hold ELEVATION DOWN and SPEED DOWN at the same time for 3-5 seconds. The display should now read Manager Mode.
b. Press any UP arrow key to go to Engineering Mode and press ENTER.
c. Press any UP or DOWN arrow key until RPM Parameter is showing on the display (Figure A).

e. If the belt does not start, replace the MCB.
f. If the Parameter does not show a value, replace the console.
FIGURE A
FIGURE B
ERROR MESSAGE 0x0043
1) CAUSE - RPM read from RS232 does not match RPM read from the speed sensor - only used for AC motors.
2) SOLUTION
a. Press and hold ELEVATION DOWN and SPEED DOWN at the same time for 3-5 seconds. The display should now read Manager Mode.
b. Press any UP arrow key to go to Engineering Mode and press ENTER.
c. Press any UP or DOWN arrow key until RPM Parameter is showing on the display (Figure A).

e. If the belt does not start, replace the MCB.
f. If the MCB does not resolve issues, replace the Daughter Board (Figure C).
g. If the Parameter does not show a value, replace the console.
FIGURE A FIGURE B
FIGURE C
CHAPTER 8: TROUBLESHOOTING