Specifications

to avoid the problem, but it is rare and backup RPD will restart and the system will
recover without intervention. PR830057
While performing GRES, the following error message appears: Feb 24 21:23:57 striker1
license-check[1555]: LIBJNX_REPLICATE_RCP_ERROR: rcp -T
re0:/config/license_revoked.db /config/license_revoked.db.new : rcp:
/config/license_revoked.db: No such file or directory This error is seen when no license
is revoked on the master Routing Engine. It is safe to ignore as it will not affect any
licensing functionality. PR859151
Interfaces and Chassis
Interrupt storm happened when press craft button with "craft-lockout". PR870410
On the PTX Series, while deactivating or activating a firewall filter that has tcp-flags
in the match condition on a loopback interface (e.g. lo0.0), memory corruption could
occur when the filter configuration is pushed to the Packet Forwarding Engine, or is
removed from the Packet Forwarding Engine, causing all the FPCs to crash and generate
core files. The following is logged by the FPCs a few seconds prior to the failure:
fpc1 dfw_match_branch_db_destroy:77filter index 1, dfw 0x20bb2a90, match_branch_db
not empty on filter delete
fpc2 dfw_match_branch_db_destroy:77filter index 1, dfw 0x205a6340, match_branch_db
not empty on filter delete
fpc0 dfw_match_branch_db_destroy:77filter index 1, dfw 0x20471c38, match_branch_db
not empty on filter delete
PR874512
FPC crash can be triggered by a SBE event after accessing a protected memory region,
as indicated in the following log: "System Exception: Illegal data access to protected
memory!" The DDR memory monitors SBEs and reports the errors as they are
encountered. After the syslog indicates a corrupted address, the scrubbing logic tries
to scrub that location by reading and flushing out 32-byte cache line containing that
location in an attempt to update that memory location with correct data. If that memory
location is read-only, it causes illegal access to protected memory exception as reported
and resets the FPC. The above-mentioned scrubbing logic is not needed because even
if SBE is detected, the data is already corrected by the DDR and CPU has a good copy
of the data to continue its execution path. PR919681
100GE interfaces on the PTX Series do not display PCS BIP-8 error counters when
queried from the FPC command show mtip-cgpcs <> errors. PR920439
USB install failed with 13.3B1-PS.1. PR931231
Layer 2 Features
In some configurations, the MAC address of an AE bundle would fail to be copied to
its child interfaces. This causes the destination MAC address filter check to fail on those
child interfaces, thus preventing ARP resolution and in turn causing the failure in
establishing new egress LSPs.
The workarounds are identified as the following:
Issuing "commit full" on the router, or
Copyright © 2015, Juniper Networks, Inc.182
Release Notes: Junos OS Release 13.3R6 for the EX Series, M Series, MX Series, PTX Series, and T Series