Specifications

ae0 of switch C 4. enable iccp link of router A. (Please wait until iccp status up.) 5.
enable ae0 of switch C 6. enable ae0 of router A. PR982713
When upgrading to 13.3R2, customer may see the following messages: Chassis control
process: rtslib: ERROR kernel does not support all messages: expected 104 got 103,a
reboot or software upgrade may be required Chassis control process: Chassis control
process: rtslib: WARNING version mismatch for msg macsec (103): expected 99 got
191,a reboot or software upgrade may be required Chassis control process: Chassis
control process: rtslib: ERROR kernel does not support all messages: expected 104 got
103,a reboot or software upgrade may be required Chassis control process: Chassis
control process: rtslib: WARNING version mismatch for msg macsec (103): expected
99 got 191,a reboot or software upgrade may be required These messages are generated
during validating the new chassis management daemon against the old kernel, and
are harmless. PR983735
1GbE SFP(EX-SFP-1FE-LX) output optical power is restored after reseating by manual
removal/insert of SFP although the IF is disabled. PR984192
SNMP OID VRRP-MIB::vrrpAssoIpAddrRowStatus returns only one Ip address when
the interface ifl has configured with two virtual-addressees under two vrrp-groups.
PR987992
Following messages could be seen on the router for the FPC slot which are even empty.
These messages are cosmetic and could be ignored. chassisd[1637]: %DAEMON-6:
FPC 0 does not support Pic power off config cmd ignoring the config change
chassisd[1637]: %DAEMON-6: FPC 2 does not support Pic power off config cmd
ignoring the config change. PR988987
CFMD may crash after configuration change of an interface in a logical system which
is under OAM config for a l2vpn instance. PR991122
Layer 2 Features
When DHCP local server and DHCP relay are both configured on same router, the DHCP
relay binding might get lost if a graceful Routing Engine switchover (GRES) is performed.
PR940111
In L3 Wholesale environment, the DHCP clients might fail to renew their address in
DHCP relay scenario. PR956675
Configuring Ethernet Ring Protection Switching (ERPS), after changing interface's
MTU on Ring Protection Link (RPL) owner, all the interfaces on RPL owner change into
forwarding state, hence cause a layer 2 loop. PR964727
On MX Series platform with Ethernet Ring Protection Switching (ERPS) configuration,
after disabled Ring Protection Link (RPL) interface and then move RPL from west
interface to east interface, as a result, the ERPS east and west interface might go into
discard state at same time. PR970121
In DHCPv6 subscriber environment, changing the c-tags (inner vlan) without clear the
DHCPv6 clients first is not recommended, it might cause the subscriber to use the old
inner vlan even after DHCPv6 RENEW process. PR970451
117Copyright © 2015, Juniper Networks, Inc.
Resolved Issues