Specifications

24
MX Protection, Control and Monitoring Features FCD LMENTB2300-01 – 07/08
European Directives
All MX actuator designs have been tested to comply with pertinent EU Directives and shipped with the
Declaration of Conformity listed in the Regulatory Section of LMENIM2306 and LMENIM2314. The
actuator is also tagged with the CE mark to demonstrate compatibility with the following European
Directives:
Directives 98/38/EC- Machinery, 89/336/EC- EMC – Electromagnetic Compatibility, 73/23/EC & 93/68/
EC – Low Voltage, and 2003/10/EC Airborne Noise.
Directives 89/336/EC- Machinery and 73/23/EC & 93/68/EC – LVD; EN 60204 EMC
Vibration and seismic capability in accordance with MILSTD-167, IEEE-344-1975, and IEC68-•
2-6. Vibration consists of 5-200-5 Hz sweeps at 0.75 g acceleration in three axes and 2-35 Hz
at 1.0 g acceleration in three axes. Seismic is 5.0 g acceleration from 3.5-35 Hz in three axes.
Drop test – ASTM D3332-88, method A as guideline only.•
Temperature extremes with humidity – Confirm function of motor, controls, and output torque •
at -30°C (-22°F) for 72 hours continuous, 70°C (158°F) dry heat for 16 hours continuous and
70°C (158°F) damp heat for 72 hours continuous. The MX has also been subjected to arctic
extremes down to -60°C (76°F) and maximum temperatures to 40°C (+104°F). The maximum
temperature is limited by the lubrication viscosity.
Di-electricMotor per NEMA MG1-12.02 and .03 with leakage of less than 10 mA. Control •
terminals per IEC-1131-2 and CSA C22.2 with check against physical breakdown.
Directives 98/37/EC- EMC & 73/23/EC & 93/68/EC – LVD; EN 50081-1 & 2
Applicable Emissions Standards; EN 50011:1998•
Radiated emissions; EN 55011:1998 & FCC Part 15, subpart J•
Conducted emissions; EN 55011:1998 & FCC Part 15, subpart J•
Applicable Immunity Standards; IEC EN 61000-6-1:2001•
ESD; IEC 61000-4-1:1995•
Radiated RF Immunity; IEC 61000-4-3:1995•
Fast Transients and Bursts; IEC 61000-4-4:1995•
Voltage Surges; IEC 61000-4-5:1995•
Conducted RF Immunity; IEC 61000-4-6:1996•
Magnetic Field Immunity; IEC 61000-4-8:1993•
Voltage Dips and Interrupts; IEC 61000-4-11:1994•
Directive 2003/10/EC Airborne Noise to EN 60204-1
Airborne sound – 74 dB (at 200 RPM) per grade A noise requirement of MIL-STD-740 and •
ANSI/ISA-S82.01-1994 (Harmonized std. to IEC 1010-1).