Technical data

Connections
SINAUT MD720-3
C79000-G8900-C210
11
2.3 Remote configurations by GSM data call
Using a modem (analog, ISDN, GSM) a PC, functioning as configuration computer,
can establish a data connection to a SINAUT MD720-3. The SINAUT MD720-3
only accepts calls that identify themselves with the right telephone number
registered before in the SINAUT MD720-3 (CLIP).
According to the transmitted CLIP the incoming call will be connected to the
internal Service Interface of the SINAUT MD720-3 or to the control which is
connected.
GSM data call S7-200 Õ Configuration computer
Figure 2-4
Remote configurations of the S7-200 by CSD data call
When a call goes to the connected control this control switches to the PPI mode.
Then a software update is possible.
GSM data call SINAUT MD720-3 (Service mode) Ù Configuration computer
Figure 2-5
Remote configurations of the SINAUT MD720-3 by CSD data call
A call to the Service Interface of the SINAUT MD720-3 must be established as
PPP-connection. Then it is possible to update the software of the device via FTP
protocol (refer to chapter 9.4 Service calls in OPC mode).
S7-200 PPI
SINAUT
MD720-3
GPRS/
GSM
Fixed net
Configuration
computer
S7-200 PPI
SINAUT
MD720-3
GPRS/
GSM
Fixed net
Configuration
computer