Technical data

SINAUT Diagnostics and Service tool
3.7 Messages in the diagnostic buffer of the CPU
Software
System Manual, 07/2009, C79000-G8976-C222-07
425
The TD7 diagnostic messages in hexadecimal and plain text format
The following table shows or SINAUT TD7 diagnostic messages according to their event IDs
numbers in ascending order in hexadecimal format.
Most diagnostic messages have additional information added to them. If the diagnostic
messages are displayed as text, this additional information is included in the texts suitably
formatted.
In the explanations below, this additional information is specified within the texts as [Info1] or
[Info2/3]. If the texts are not shown, the additional information is shown as 'Additional info 1 /
2 / 3' in the hexadecimal representation on the PG.
Table 3- 22 SINAUT diagnostic messages of TD7onCPU
No. Event ID
(hex)
Meaning
Parameter assignment errors, configuration errors
0 B100 Parameter assignment error for object no. [Info1]: PartnerNo [Info2/3] not permitted.
1 B101 Parameter assignment error for object no. [Info1]: PartnerNo [Info2/3] unknown.
2 B102 Parameter assignment error for object no. [Info1]: PartnerObjectNo [Info2/3] not permitted.
3 B103 Parameter assignment error for object no. [Info1]: ST1 message no. [Info2/3] not permitted.
4 B104 Parameter assignment error for object no. [Info1]: ST1 object no. [Info2/3] not permitted.
5 B105 Parameter assignment error for object no. [Info1]: ST1 index no. [Info2/3] not permitted.
6 B106 Parameter assignment error for object no. [Info1]: ST1 PACK value [Info2/3] not permitted.
7 B107 Errors generating the object reference list: DB[Info1] cannot be created. Cause: [Info2/3].
8 B108 Parameter assignment errors in the object reference list: Reference to subscriber no. [Info1] and
object no. [Info2/3] exists more than once.
9 B109 Object reference list 1 missing. Searching for reference to subscriber no. [Info1] and object no.
[Info2/3].
10 B10A Object reference list 2 missing. Searching for reference to subscriber no. [Info1] and object no.
[Info2/3].
11 B10B Parameter assignment errors in object reference list 1: Reference to subscriber no. [Info1] and
object no. [Info2/3] missing.
12 B10C Parameter assignment errors in object reference list 2: Reference to subscriber no. [Info1] and
object no. [Info2/3] missing.
13 B10D Error in object DB no. [Info1]: SINAUT ST7 ID A5h missing.
14 B10E Configuration error: No subscriber contained in DB BasicData (DB[Info1]) .
15 B10F Unknown connection type for connection no. [Info1] to local subscriber no. [Info2/3].
16 B110 Unknown subscriber type (= [Info1]) for subscriber no. [Info2/3].
17 B111 Data received from an unknown local communication partner (MPI no. = [Info2/3]).
18 B112 In the send buffer of communication DB no. [Info1], an org. message with an unknown destination
subscriber (= [Info2/3]) was deleted.
19 B113 Parameter assignment error for FC [Info1] in parameter [Info2/3].
20 B114 Parameter assignment error object no. [Info1] in parameter [Info2/3].