Technical data

SINAUT Diagnostics and Service tool
3.6 Messages in the diagnostic buffer of the TIM
Software
System Manual, 07/2009, C79000-G8976-C222-07
419
Event ID
(hex)
Detailed
event
(hex)
Meaning
F560 0531 MesA - Error in the request for an Org4/14 message.
F560 0532 MesA - Unknown control command received.
F560 0533 MesA - Error in MesA system status list query.
F560 0534 MesA: Bad PDU detected.
Messages from clock driver
F560 0620 Installation of clock driver aborted.
F360 0621 for error code = 0: Installation of the clock driver completed
for error code = 1: Installation of clock driver aborted.
F560 Entering state: Time synchronization (master) disturbed.
F460
0622
Exiting state: Time synchronization (master) OK.
F960 Entering state: Time synchronization (slave) disturbed.
F860
0623
Exiting state: Time synchronization (slave) OK.
F560 0624 Error occurred setting the RMOS clock.
F560 0625 Error occurred reading the RMOS clock.
F360 0626 Illegal setting of the RMOS clock by
Set clock
PG service. TIM has onboard DCF77 clock.
F360 0627 Unknown message received.
F360 0628 Time synchronization PDU with incorrect ORG number received.
F360 0629 Bad synchronization PDU received from LAN.
F560 Entering state: Time synchronization by DCF77 clock disturbed.
F460
062A
Exiting state: Time synchronization by DCF77 clock OK.
F960 Entering state: DCF77 clock radio signal disturbed.
F860
062B
Exiting state: DCF77 clock radio signal OK.
F360 062C TIM time OK. RMOS clock set for the first time.
F360 Entering state: Changeover to daylight saving time.
F260
062D
Exiting state: Changeover to standard time.
F360 Entering state: Notification hour for daylight saving/standard time changeover active.
F260
062E
Exiting state: Notification hour for daylight saving/standard time changeover completed.
F360 0630 Change in synchronization mode.
F360 0631 Daylight saving/standard time changeover performed manually.
F360 0632 Error occurred in manual daylight saving/standard time changeover.
F560 0633 Error occurred starting the synchronization task.
F560 0634 Error occurred starting the control task for synchronization.
F960 0635 Two time masters detected in one network.
F960 0636 Incorrect synchronization mode on MPI. Master mode expected.
F960 0637 No further module exists on MPI bus/party line.
F560 0638 External / internal WAN interface: A subscriber could not be synchronized following restart.
F360 0639 Error detected in time-of-day synchronization.
F360 063A Bad time-of-day message received from DCF77 module.
F360 063B Bad time-of-day message received from DCF77 module.
F360 063C Time jump occurred.
F360 063D Bad time-of-day message received from DCF77 module.