Service manual

7
AUTO CALIBRATION PROCEDURE
After initial installation or replacement of the incline motor, auto
calibration should be run.
1) Press ENTER, 2, 0, 0, 1, ENTER on the keypad to go into
Engineering Mode.
2) Press CALIBRATION on the display.
3) Press AUTO CALIBRATION on the display.
4) Press START on the display.
5) This will run the Auto Calibration. If the calibration passes, it will
say complete. Press the HOME key to return to the normal start
screen.
6) If the calibration does not pass, contact Matrix Customer
Technical Support at 866-693-4863 ext 3.
3.5 AUTO CALIBRATION PROCEDURE
TOUCH SCREEN CARE AND CLEANING
* The touch screen requires very little maintenance. We
recommend that you periodically clean the touch screen surface
with a dry soft cloth. If necessary, we recommend the usage of
Alcohol or Isopropyl Alcohol for difficult stains or sanitary purposes.
* It is very important to avoid using any other chemical on the
touch screen.
* Always dampen the cloth and clean the screen. Do not spray
the cleaning agent on the screen itself, the drips can seep into the
display or stain the bezel.
* After cleaning, make sure the surface is dry. There should not be
any left over solvent to seep into the display.
* It is very important to handle the touch screen with care. Do not
use excessive force when cleaning.
* Do not use any sharp materials to clean the touch screen
surfaces.
* Do not use high pressure air, water, or steam to clean the touch
screen surface.
3.4 TOUCH SCREEN CARE & CLEANING
CHAPTER 3: PREVENTATIVE MAINTENANCE