4-2-2. Power ON / OFF / REMOTE (Main) switch: 
a. Before installing the inverter, you need to ensure the main switch 
is in the OFF position. 
b. Before using the remote unit, you need to ensure the main switch 
is in the REMOTE position. 
4-2-3.  AC input Circuit Breaker: 
The AC input circuit breaker protects the model from overload. 
When an overload condition exists, the circuit breaker stops to supply 
output AC grid power. To reset it, push the circuit breaker switch 
then the model will be back in normal operation. The source fault 
should be corrected before you reset it. 
4-2-4. Remote Port:
 The ST Series Inverter is compatible with any of these remote 
controllers: CR-6, CR-7 or CR-8. 
4-2-5. DC Input Terminals: 
Connect DC input terminals to 12V / 24V / 48V battery or other 
power sources. 
[ + ] represents positive, [ - ] represents negative. Reverse polarity 
connection can blow the internal fuse and may damage the inverter 
permanently. 
DC Input Voltage  
Model 
Minimum  Maximum 
12V 10.5V 15.0V 
24V 21.0V 30.0V 
48V 42.0V 60.0V 