User's Manual
3-2-2. Connect AC output and AC input wiring to the ST series 
terminals. Please take the following information as your reference. 
Wire length / gauge 
Terminal Wire color
ST1000&ST1500 
ST2000&ST2500
Line (L)  Black 
AC 
OUTPUT 
Neutral (N)  White 
 Line (L)   Brown 
AC 
INPUT 
Neutral (N)  Blue 
Ground 
Green / 
Yellow or 
Bare copper 
Within 16 feet / AWG# 
 14~16 
26~32 feet / AWG# 
12~14 
Within 16 feet / AWG#
 10 ~12 
26~32 feet / AWG# 
8 ~10
 3-2-3. Please double check and review all connections to ensure 
the wires are in correct terminals and the connections are tight. 
3-2-4. 
 Before connecting AC output and AC input terminals of the ST series, 
you can either use front compartment cover or a side hole to coil out. 
Both AC input and AC output are coiled out from the front compartment 
cover when in production. If you want to change the position, you 
should open the top cover first, and then switch the wire of the front 
compartment cover and the plastic cover of the side of top cover. 
ST1000
ST1500
1
0
INPUT 
LEVEL
0
I
PORT
REMOTE 
ON-OFF-REMOTE
POWER
NEG(-)
REVERSE POLARITY 
WILL DAMAGE UNIT
POWER
STATUS
S
4
S
3
S
2
S
1
LOAD 
LEVEL
BREAKER
POS(+)
DC INPUT
AC INPUT
13