User's Manual
3. Installation 
 3-1.Where to install 
The power inverter should be installed in a location that meets the following 
requirements: 
3-1-1.  Dry – Do not allow water to drip or splash on the inverter. 
3-1-2. 
Cool – Ambient air temperature should be between 0℃ and 40℃, 
the cooler the better. 
3-1-3.  Safety – Do not install batteries in compartment or other areas 
where flammable fumes existence such as fuel storage areas or 
engine compartments. 
3-1-4.  Ventilated – Allow at least one inch of clearance around the 
Inverter for air flow. Ensure the ventilation shafts on the rear 
and bottom of the unit are not obstructed. 
3-1-5.  Dust-free – Do not install the Inverter in a dusty environments 
where dust, wood particles or other filings/shavings are 
present. The dust can be pulled into the unit when the cooling fan is 
operation. 
3-1-6.  Close to batteries – Avoid excessive cable lengths but do not install 
the inverter in the same compartment as batteries. 
Use the recommended wire lengths and sizes (see section 4-3). 
Do not mount the inverter at the place where it is exposed to the 
gases produced by the battery. 
These gases are very corrosive and prolonged exposure will 
damage the inverter. 
 WARNING! 
 Shock Hazard. Before proceeding further, carefully 
check that the inverter is NOT connected to any 
batteries, and that all wiring is disconnected from any 
electrical sources . Do not connect the output terminals 
of the inverter to an incoming AC source.
11