User Manual
Description This command shifts the strip chart left or right. [ref] determines both
which strip chart is used and which direction it will shift. The direction
is selected by the most significant bit (MSB):
• MSB: 0 shifts left
• MSB: 1 shifts right
For example if [ref] is 1:
• 254 107 1 (hex FE 6B 01) shifts left
• 254 107 129 (hex FE 6B 81) shifts right
This command shifts the contents of the area defined in the Initialize
Strip Chart command 8 pixels at a time.
Remembered No
9 General Purpose Output
9.1 Introduction
General purpose outputs allow you to connect devices, such as LEDs, to the GLK12232-25 and supply
them with up to 20mA of current at 5V. The GLK12232-25 has 2 GPOs which are software controlled, with
functions to turn them on/off and set the power state for the next startup.
9.2 General Purpose Output Off
Syntax
Hexadecimal 0xFE 0x56 [Num]
Decimal 254 86 [Num]
ASCII 254 “V” [Num]
Parameters
Parameter Length Description
Num 1 GPO number.
Description This command turns OFF general purpose output [num].
NOTE OFF means that the output is pulled HIGH.
Remembered Yes
9.3 General Purpose Output On
Matrix Orbital GLK12232-25 34