Installation Instructions
3299 Tower Drive
Newburgh, IN 47630
812.490.1525
www.MatrixTeam.com
9
Preliminary
13
Relay Out 1
Mechanical Relay 1
Common
Configurable
14
Input B9
Digital Input 9 Common
Configurable
De-Actuate 0-55VAC or 0-6VDC
15
Chassis
Chassis Ground
Machine Ground
16
Input A4
Digital Input 4
Configurable
Actuate 65-150VAC or 9-25VDC
17
4-20 Input 0 +
Analog Input 0
Configurable
18
Input B3
Digital Input 3 Common
Configurable
De-Actuate 0-55VAC or 0-6VDC
19
Input A6
Digital Input 6
Configurable
Actuate 65-150VAC or 9-25VDC
20
CAN Bus 1 High
CAN Communication 1 High
Configurable
21
CAN Bus 1 Low
CAN Communication 1 Low
Configurable
22
Common
Power Supply Common
23
Input B5
Digital Input 5 Common
Configurable
De-Actuate 0-55VAC or 0-6VDC
24
Input A8
Digital Input 8
Configurable
Actuate 65-150VAC or 9-25VDC
25
4-20 Input 1 -
Analog Input 1 Common
Configurable
26
+24VDC
Power Supply Input Voltage
27
CAN Bus 0 High
CAN Communication 0 High
Configurable
28
Input A9
Digital Input 9
Configurable
Actuate 65-150VAC or 9-25VDC
29
+72VDC
Power Supply Input Voltage
30
4-20 Output 0 +
Analog Output 0
Configurable
31
Input B4
Digital Input 4 Common
Configurable
De-Actuate 0-55VAC or 0-6VDC
32
Input A3
Digital Input 3
Configurable
Actuate 65-150VAC or 9-25VDC
33
4-20 Output 0 -
Analog Output 0 Common
Configurable
34
Input B6
Digital Input 6 Common
Configurable
De-Actuate 0-55VAC or 0-6VDC
35
4-20 Input 1 +
Analog Input 1
Configurable
36
4-20 Input 0 -
Analog Input 0 Common
Configurable
37
Input A5
Digital Input 5
Configurable
Actuate 65-150VAC or 9-25VDC
38
Input B8
Digital Input 8 Common
Configurable
De-Actuate 0-55VAC or 0-6VDC
39
4-20 Output 1 +
Analog Output 1
Configurable
40
4-20 Output 1 -
Analog Output 1 Common
Configurable
41
CAN Bus 0 Low
CAN Communication 0 Low
Configurable
42
Common
Power Supply Common
Controller Inputs
Digital Inputs
There must be 10 optically isolated digital inputs available. The actuation / de-actuation levels are listed in
Table 3. All inputs must remain in the de-actuated state when left floating. The usage of each input is
specified in the Interface Specification for each application of the proximity detection system.