COSEC ATOM Safety Instructions ATOM RD300 ATOM RD200 These instructions are intended to ensure that the user can use the product correctly to avoid danger or property loss. Cautions Do not install the device: Ÿ Ÿ Ÿ Ÿ Where ferromagnetic field or noise is induced. Where static is created, such as desks made of plastics, carpets. Near volatile inflammable materials or inflammable goods such as drapes. Ÿ Where volatile gas and/or inflammable gas is created.
Contents Know your ATOM Ÿ COSEC ATOM is a slave reader which can work with COSEC ARGO, Know your ATOM 4 What your Package Contains 6 COSEC VEGA, COSEC PATH V2 using RS-232 and with COSEC ARC DC200 using RS-485. It can also work with 3rd party Wiegand Interface. Things you will Need 6 Ÿ It is an intelligent compact Access Control Device which supports Installation 7 Bluetooth and Card Credentials for Access Control and Time & Attendance.
What your Package Contains Type 2: COSEC ATOM RD200 1. LED Indicator 2. Finger Sensor 3. Mounting Screw Hole 4. Cable Assembly 5. Mounting Plate 1 3 4 Sub Variants 5 3 Figure 3: Front View Figure 4: Back View Ÿ Ÿ Ÿ Ÿ ATOM RD200MFM ATOM RD200MFI ATOM RD200SFM ATOM RD200SFI Type 3: COSEC ATOM RD100 1 1. LED Indicator 2. Numeric Keypad 3. Mounting Screw Hole 4. Cable Assembly 5.
Installation Step 2: Connecting the Cables 1) Installing the COSEC ATOM RD200/300: Wall Mounting Ÿ You can mount COSEC ATOM RD200/300 in two ways : Concealed Wiring or Non-concealed Wiring as explained below. Step 1: Removing the Mounting Plate Ÿ From the bottom of the COSEC ATOM RD200/300, unscrew the Mounting screw with the help of screw driver as illustrated in Figure 8. Ÿ Separate the Mounting plate from the ATOM by pulling it downwards. Refer, Figure 9 for the same. A. Concealed Wiring 1.
2. Affix the mounting plate with the help of the screws and screw grips through the holes A, B and C. 3. Lead the cables from the wall through the drilled area D of the Mounting Plate as illustrated in Figure 12. Connect the necessary cables with COSEC ATOM.
B. Non-Concealed Wiring 1. Follow the Step 1 and Step 2 as explained for the Concealed Wiring and fix the mounting plate on the wall. 3.Pull out the Cables from the Back Plate hole and lead the cables outside from the bottom opening of COSEC ATOM, as illustrated in Figure 14. (For non-concealed wiring, you do not need to drill the area D.) Back Plate Figure 14 Figure 13 2. Unscrew the Back Plate screw with the help of screwdriver and remove the Back Plate. 11 4.
2. Slide the reader downwards to fix it into the groove of the Mounting Plate and insert the Mounting screw back in place at the bottom of the device. 3. Tighten the screw with 2 kgf-cm torque as shown in Figure 17. Figure 15 Step 3: Inserting Mounting Screw 1. Fix the Reader body with the Mounting Plate such that the Mounting Slots of the Reader and Mounting Plate align with each other.
2) Installing the COSEC ATOM RD200/300: Flush Mounting Step 1: Take the Surface Mount Plate provided with the package and trace screw holes A, B, C and D on the surface where COSEC ATOM is to be installed, see Figure 18. After tracing drill along the markings as shown in Figure 19. A B A B D C Figure 19 Step 2: Assemble the device with the Surface Mount Plate as shown in Figure 20.
Step 3: To connect the cables refer below image for Concealed and Non-concealed Wiring positions.
Step 4: Affix the Surface Mount Plate with the Device on the surface with the help of the screws and screw grips through the holes A, B, C and D, see Figure 21. Step 5: Place the Surface Mount Top Facia Plate on the installed Device, see Figure 22.
3) Installing the COSEC ATOM RD100 Step 2: Connecting the Cables Step 1: Removing the Mounting Plate Ÿ You can mount COSEC ATOM in two ways : Concealed Wiring or Non-concealed Wiring as explained below. Ÿ From the top of the COSEC ATOM, unscrew the Mounting screw with the help of screw driver as illustrated in Figure 24. Ÿ Separate the Mounting Plate from the ATOM by pulling it downwards. Refer, Figure 25 for the same. A. Concealed Wiring 1. Take the Mounting Plate and trace screw holes A & B.
2. Affix the Mounting Plate with the help of the screws and screw grips through the holes A and B. 3. Lead the cables from the wall through the drilled area C of the Mounting Plate as illustrated in Figure 24. Connect the necessary cables with COSEC ATOM, see Figure 28.
B. Non- Concealed Wiring 1. Follow Step 1 and Step 2 as explained for the Concealed Wiring and fix the Mounting Plate on the wall. (For non-concealed wiring, you do not need to drill the area C.) 2. Unscrew the Back Plate screw with the help of screwdriver and remove the Back Plate. 3.Pull out the Cables from the Back Plate hole and lead the cables outside from the bottom opening of COSEC ATOM, as illustrated in Figure 30. Back Plate Figure 29 Figure 30 4.
Figure 32 2. Slide the reader downwards to fix it with the groove of the Mounting Plate and insert the mounting screw back in place on top of the device. Figure 31 Step 3: Inserting Mounting Screw 1. Fix the Reader body with the Mounting Plate such that Mounting Slots of the Reader and Mounting Plate align with each other. 27 3. Tighten the screw with 2 kgf-cm torque as shown in Figure 33.
Technical Specifications Specification Parameters ATOM RD300 Credential Support PIN, RFID Card, Mobile Credential over BLE and Finger ATOM RD100 RFID Card, Card, Mobile Mobile Credential Credential over BLE and over BLE Finger User Capacity Depends on Master Device **Type of Card HID I - class, MIFARE / Desfire / Combo Cards / NFC Card Read Range R R MIFARE -5 cm or more, R MIFARE -6 cm Desfire Ev1-Atleast 4 cm or more, Desfire Ev1-Atleast 4 cm Reader Interface Type RS-232, RS-485, WIFI and
LED and Buzzer Indications State ATOM RD100/200: Connected through RS-232/ RS-485 State Power On Blue (ON) Buzzer OFF Idle Online Blue (ON: 200ms OFF: 2200ms) OFF Idle Offline/ Network Failure Red (ON: 200ms OFF: 2200ms) OFF Degraded Mode Orange (ON: 200ms OFF OFF: 2200ms) Processing Green (ON: 200ms) Red (ON: 200ms) OFF Wait Green (ON: 200ms) Red (ON: 200ms OFF: 800ms) ON: 200ms OFF: 1000ms Alarm Minor 31 Single LED (tri color) Buzzer Single LED (tri color) Alarm Clear OFF OFF Ac
State Buzzer ATOM RD100/200/300: Connected through Wiegand Interface State 33 Processing No Change Wait ON: 200ms OFF: 1000ms Alarm Minor ON: 200ms OFF: 1000ms Alarm Major ON: 400ms OFF: 800ms Alarm Critical ON till Reset Alarm Clear OFF Access Allowed ON: 1200ms Access Denied ON: 200ms OFF: 200ms 3 Cycles System Default ON till Reset Lost Connectivity with the ARC Controller OFF Idle Single LED (tri color) Blue (ON: 200ms OFF: 2200ms Buzzer No Change Card Detection/ Green (ON: 10
Connecting the Reader 1. RS-232 connectivity for COSEC Doors, COSEC VEGA, COSEC PATH and COSEC ARGO. 2. RS-485 connectivity for COSEC ARC. 3. Wiegand connectivity for 3rd party Access Control Panel.
Caution: FCC Compliance Disposal of Product after End-Of-Life This device complies with part15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits of Class A digital device, pursuant to part 15 of the FCC Rules.