User`s guide
set (scope object)
Property Description Writable
As a special case, setting TriggerSam ple
to -1 means that the current scope is
triggered at the end of the acquisition cycle
of the triggering scope. Thus, the first
sample of the triggering scope is a cquired
one sample after the last sample of the
triggering scope.
TriggerScope
If TriggerMode is 'Scope', identifies the
scope to use for a trigger. A scope can
be set to trigger when another scope is
triggered. You do this by setting the slave
scope property
TriggerScope to the scope
index of the master scope.
Yes
TriggerSignal
If TriggerMode is 'Signal', identifies the
block output signal to use for triggering
the scope. You identify the signal with a
signal index from the targ et object property
Signal.
Yes
TriggerSlope
If Trig gerM ode is 'Signa l',indicates
whether the trigger is on a rising or falling
signal. Values are
'Either' (default),
'Rising',and'Falling'.
Yes
Type
Determines whether the scope is displayed
on the host computer or on the target
computer. Values are
'Host', 'Target',
and
'File'.
Yes
18-122