User`s guide
get (target application object)
Property Description Writable
LogMode
Controls which data points are logged:
• Time-equidistant logging. Logs a data
pointateverytimeinterval. Setvalue
to
'Normal'.
• Value-equidistant logging. Logs a data
point only when an output signal from
the
OutputLog changes by a specif ied
value (increment). Set the value to the
difference in signal values.
Yes
MaxLogSamples
Maximum number of samples for each
logged signal wi thin the circular buffers
for
TimeLog, StateLog, OutputLog,and
TETLog. StateLog and OutputLog can
haveoneormoresignals.
This value is calculated by dividing th e
Signal Logging B uffer S ize by the
number of logged signals. The Signal
Logging Buffer Size box is located
at Sim ulation menu Configuration
Parameters > xPC Target options
pane.
No
MaxTET
Maximum ta sk execution time.
Corresponds to the slowest time (lo ngest
time measured), in seconds, to update
model equations and post outputs.
No
MinTET
Minimum task execution time.
Corresponds to the fastest time (smallest
time measured), in seconds, to update
model equations and post outputs.
No
18-51