User`s guide

11 xPC Target™ Web Browser Interface
3 In the Target selection section, access levels are set in the System
target file box. For example, to set the access level to
1,enter
xpctarget.tlc -axpcWWWAccessLevel=1
The effect of not specifying -axpcWWWAccessLevel is tha t the h ighest
access lev e l (0) is set.
4 Click OK.
The various fields disappear, depending on the access level. For example, if
your access level does not allow you access to the parameters, you do not see
the button for parameters.
There are various access levels for monitoring, which allow different levels
of hiding. The proposed s etup is described below. Each lev el builds on
the previous one, so o nly the incremental hiding of each successive level is
described.
Level 0 Full access to all panes and functions.
Level 1 C annot change the sample and stop times. C annot change
parameters, but can view parameters.
Level 2 Cannot start and stop execution of the target application or log
data.
Level 3 Cannot view parameters. Cannot add new scopes, but can edit
existing scopes.
Level 4 Cannot edit existing scopes on the Scopes pane. C annot add or
remove signals on the Scopes pane. Cannot view the Signals pane and the
Param ete rs pane, and cannot get scope data.