User`s guide
3 Signals and Parameters
10 From the File menu, select Save As and enter a filename. For example,
enter
my_xpc_osc6.mdl and then click OK.
11 Build and download the target application. In the Simulink window and
from the Tools menu, select Real-Time Workshop.FromtheReal-Time
Workshop subm enu, select Build M odel .
The xPC Target software downloads the target application to the default
target PC.
12 In the Simulink window, and from the Simulation menu, select External .
A check mark appears next to the menu item External, and Simulink
external mode is activated.
13 If a Scope window is not displayed for the Scope block, double-click the
Scope block.
A Scope window is displayed.
14 In the Simulink window , and from the Simulation menu, select Connect
to target.
15 From the Simulation menu, select Start Real-Time Code.
The target application begins running on the target PC and the Scope window
displays plotted data.
3-54