User`s guide

Target Object
6-7
MaxLogSamples
Maximum number of samples for each logged
signal within the circular buffers for
TimeLog,
StateLog, OutputLog, and TETLog. StateLog
and
OutputLog can have one or more signals.
This value is calculated by dividing the Signal
Logging Buffer Size by the number of logged
signals. The
Signal Logging Buffer Size box
is located at Simulation Parameters dialog
box> Real-Time Workshop page >
Category:xPC Target code generation options
group.
NumLogWraps
The number of times the circular buffer
wrapped. The buffer wraps each time the
number of samples exceeds
MaxLogSamples.
LogMode
Controls which data points are logged.
Equi-distant time. Logs a data point at
every time interval. Set value to
’normal’.
Equi-distant amplitude. Logs a data point
only when one of the output values from the
OutputLog changes by a specified
amplitude. Set value to a signal value.
Yes
Scopes
List of index numbers with one index for each
scope.
NumSignals
The number of signals from your Simulink
model that are available to be viewed with a
scope.
ShowSignals
Flag set to view or hide the list of signals from
your Simulink blocks. This list is shown when
you display the properties for a target object.
Values are
’on’ or ’off’.
Yes
Table 6-1: List of Target Object Properties
Property Description Write