CAN-AC2-ISA
16-9
Setup-block
Every SIMULINK-model which sends and receives CAN-messages over the
CAN-AC2 board has to contain exactly one setup-block. The setup-block does
not have any inputs or outputs.
The dialogue-box allows to define general settings for the CAN-AC2 board. The
corresponding code (initializing the board) is executed once during the
"initializing blocks"-phase after the xPC Target application has been
downloaded.
The first dialogue-field (popup) allows to specify the memory-address range
used to access the board. The CAN-AC2 can be mapped into memory between
D0000-EFFFF. See the CAN-AC2 user’s guide for further information. If used
with xPC Target memory mapped I/O-devices can only be mapped into a
subarea of the choosable memory range of the CAN-AC2.
We recommend to use the following configurations if using xPC Target Version
1.1
2: D4000-D7FFF
3: D8000-D8FFF